Serum Anion Gap Calculator

Calculate the serum Anion Gap to assess metabolic acidosis.

Save

Inputs

mEq/L
mEq/L
mEq/L

Your values stay on this device.

Results

Anion Gap
InterpretationHigh (Metabolic Acidosis)

Report

Export and share

Document

Copy and share

Assumptions

  • This uses the standard formula without potassium, which matches many modern lab references.
  • The output assumes albumin is not severely abnormal; hypoalbuminemia can lower the measured gap.
  • Anion gap is only one part of acid-base interpretation and does not diagnose the cause by itself.

Sensitivity preview

Sodium (Na+) -10%: Anion Gap 2 mEq/L

Sodium (Na+) Current: Anion Gap 16 mEq/L

Sodium (Na+) +10%: Anion Gap 30 mEq/L

Formula: AG = Na - (Cl + HCO3)

Related Tools

View All

About this Anion Gap

The Anion Gap is a calculated value used to identify the cause of metabolic acidosis. It represents unmeasured anions in the plasma, such as albumin, phosphate, sulfates, and organic acids like lactate or ketones.

Who this calculator is for

  • Clinicians, trainees, and students reviewing electrolyte panels in acid-base cases.
  • People trying to understand why a lab report mentions a high or low anion gap.
  • Anyone learning how sodium, chloride, and bicarbonate relate in metabolic acidosis screening.

When to use it

  • Use this calculator when BMP or CMP results are available and you want the standard anion gap quickly.
  • Use it to compare how the gap changes across repeat electrolyte panels over time.
  • Use it as a teaching aid when discussing high-gap versus normal-gap metabolic acidosis.

How to use this calculator

  1. Enter the Sodium (Na+) level from the basic metabolic panel (BMP).
  2. Enter the Chloride (Cl-) level.
  3. Enter the Bicarbonate (HCO3- or CO2) level.
  4. Check the result to see if the gap is High, Normal, or Low.

Key assumptions

  • This uses the standard formula without potassium, which matches many modern lab references.
  • The output assumes albumin is not severely abnormal; hypoalbuminemia can lower the measured gap.
  • Anion gap is only one part of acid-base interpretation and does not diagnose the cause by itself.

Accuracy and testing

Review formula sources, default test cases, assumptions, unit handling, rounding rules, and changelog for this calculator.

View accuracy page

Key Features

  • Standard formula (without Potassium)
  • Interpretation guide
  • Instant electrolyte analysis

Things to Keep in Mind

This calculator uses the standard formula which assumes normal albumin levels. In patients with significant hypoalbuminemia, the corrected anion gap should be used.

Frequently Asked Questions

What is a normal Anion Gap?
A normal anion gap is typically between 8 and 12 mEq/L, though some labs use a range of 3-10 or 4-12 depending on their assays.
What causes a High Anion Gap?
High Anion Gap Metabolic Acidosis (HAGMA) is often remembered by the mnemonic MUDPILES: Methanol, Uremia (kidney failure), DKA (Diabetic Ketoacidosis), Paracetamol/Propylene glycol, Infection/Isoniazid, Lactic acidosis, Ethylene glycol, Salicylates.
What causes a Low Anion Gap?
A low anion gap is less common but can be caused by Hypoalbuminemia (low albumin), Multiple Myeloma, or Lithium toxicity.
Why is Potassium ignored in this formula?
The traditional formula (Na + K) - (Cl + HCO3) has largely been replaced by Na - (Cl + HCO3) because Potassium levels are small (3.5-5.0) and relatively constant compared to Sodium.
How does albumin affect the Anion Gap?
Albumin is a major unmeasured anion. For every 1 g/dL decrease in albumin below normal (4.0), the expected anion gap decreases by ~2.5 mEq/L. Hypoalbuminemia can mask a high anion gap acidosis.